Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Digital Matter Site
  • Contact Us

Hawk - Configure DM Temp Probe (Deprecated)

Written by Matthew Clark-Massera

Updated at October 6th, 2023

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Contact Support
  • Home
  • Devices
  • Cellular
  • Data Loggers
  • Hawk IoT Datalogger
  • I²C

Table of Contents

Related Articles Wiring Parameters Sensors - I²C Action Parameters Probe 1 Probe 2 Task Parameters Output/Conversion

Related Articles

Please ensure to also read the below for full details on configuring Tasks and I²C Sensors for the Hawk

  • Hawk Operation - Task Schedules
  • Configure I²C Sensor Readings
 

The DM Temperature Sensor is no longer manufactured by DM. If you have one on hand to use with the Hawk, setup is as below.

Wiring

Sensor Wire Agtech1 Bluetooth+
Red (3V3) Hawk IO 5 Hawk IO 7
Brown (SCL) Hawk IO 6 Hawk IO 5
Orange (SDA) Hawk IO 4 Hawk IO 6
Black (GND) Hawk GND Hawk GND
Green (Address Select) This sets the sensor's address.

Connect to GND to set as Temp Probe '1' - 150 (0x96)

Connect to Hawk IO 5 (3V3) to set as Temp Probe '2' - 158 (0x9E)
This sets the sensor's address.

Connect to GND to set as Temp Probe '1' - 150 (0x96)

Connect to Hawk IO 7 (3V3) to set as Temp Probe '2' - 158 (0x9E)

Parameters

Sensors - I²C Action Parameters

We need to configure 1 or 2 probes to be read as part of an I²C Action

Probe 1

The "default" I²C Address is 150 - so if we leave it blank, the below reads from Temp Probe 1
Probe 1 is the probe we have wired with the Green wire connected to GND

Probe 2

To read from Temp Sensor 2, set the address to 158
Sensor 2 is the sensor we have wired with the Green wire connected to 3V3.

Task Parameters

To read both during the task, set up both I²C Actions in the task. If using only 1 probe configure only 1 action etc.

Output/Conversion

With the above parameters, the output would be:

Value Analogue Units Conversion Example
Temp Probe 1 Analogue Offset Value (12) °C * 100 800 = 8°C
Temp Probe 2 Analogue Offset Value (13) °C * 100 800 = 8°C
configuration hawk

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Hawk - Configure DM Ambient (Temp+Hum Sensor)
  • Configure I²C Sensor Readings
  • Hawk - Configure MaxBotix MB7040 I²C Ultrasonic Range Sensor