Hawk - Configure Keller PR26D I2C Temp/Pressure Sensor

Written by Cameron Everett

Updated at September 23rd, 2025

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Contact Support
  • Home
  • Devices
  • Cellular
  • Data Loggers
  • Hawk IoT Datalogger
  • I²C

Table of Contents

Related Articles 3rd Party Sensor IO Card Wiring Firmware Parameters I²C Action Parameters Task Parameters Output/Conversion

Related Articles

Please ensure to also read the below for full details on configuring Tasks and I²C Sensors for the Hawk

  • Hawk Operation - Task Schedules
  • Configure I²C Sensor Readings
 

The PR26D sensor is a pressure sensor commonly used for tank level measurements. 

3rd Party Sensor

As this is a 3rd Party sensor - the advice given below is general. Always check the product datasheet direct from the manufacturer. Specific guidance on installation and usage should be obtained directly from the manufacturer. The instructions below are based on a sensor tested at the time of article writing - things may change.

 

IO Card

Ensure a plug-in IO card with an I²C interface is fitted to the Hawk.

Wiring

Keller PR26D Agtech1 Bluetooth+
VCC (Black) Hawk IO 5 Hawk IO 7
SCL (Yellow)
 
Hawk IO 6 Hawk IO 5
SDA (Blue) Hawk IO 4 Hawk IO 6
GND (White) Hawk GND Hawk GND

Firmware

The AgTech1 card firmware should be set to 1.16, and the Bluetooth Card should be set to 1.6.

  • How to Update Hawk Firmware

Parameters

I²C Action Parameters

  1. Select PR26D Pressure Sensor as the Sensor Type
  2. Choose an Analogue to write the values to (it will write 4 values).
  3. Leave everything else as 0.

Task Parameters

Ensure the I²C action you have configured above (Action 1 or 2) is set as an action of the task.

Output/Conversion

With the above parameters, the output would be:

Value Analogue Units
Pressure Analogue Offset Value 0.001 bar
Temperature Analogue Offset Value + 1 0.01°C
P-Mode Analogue Offset Value + 2 Details Below
keller pressure temperature pr26d configure pressure sensor

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Hawk - Configure WNK8010TT Pressure Sensor
  • Hawk - Configure MaxBotix MB7040 I²C Ultrasonic Range Sensor

Subscribe to Partner News

Subscribe to our mailing list to receive Digital Matter news, product and tehnical updates, and more.

Subscribe

Copyright © Digital Matter . All Rights Reserved.

Privacy Contact Support

Knowledge Base Software powered by Helpjuice

DM Logo
Expand