Table of Contents

Before you start Description Payload cURL Example

Before you start

Ensure you have reviewed:

  • Welcome to the Device Manager API
  • Device Manager ASYNC Messaging Architecture

A full list of API calls can be found at: https://api.oemserver.com/swagger/index.html.

 

Description

This can be used to immobilise an vehicle. 

It operates by toggling any device digital ouptuts with function configured as Immobiliser. When the output is connected to control an automotive relay, the starter motor is cut. 

Ensure that you follow the setup instructions below. 

  • Immobilise asset from the server
    • This wiring config is typical for when we are only using ‘server based’ immobilisation (command from server disables asset) 
       
  • Immobiliser Install - Asset starts after valid Driver ID Scan 
    • This wiring config is typical for setups where the asset will not start until a Driver ID tag is scanned. 
    • However, sending a command from the server will also disable the asset - such that even a valid tag will not start the vehicle. 

Payload

Offset

Length

Data Type

Description

0

1

BYTE

The data message has 2 bits.

 

Bit 0 (immobilisation):

True = immobiliser on. This is the logical level – physical levels
(active high/low) are determined by system parameters.

 

Bit 1 (Override)

True = override on. This locks the Bit 0 state and unlocking 
immobilisation via Driver Id is ignored. 

Examples:

0 = default, immobiliser off

1 = default, immobiliser on

2 = override, immobiliser off

3 = override, immobiliser on

 

cURL Example

curl -X 'POST' \
  'https://api.oemserver.com/v1/AsyncMessaging/Send?serial=439705' \
  -H 'accept: text/plain' \
  -H 'Authorization: Basic XXXXXXXXXXXX' \
  -H 'Content-Type: application/json' \
  -d '{
  "MessageType": 256,
  "CANAddress": 4294967295,
  "ExpiryDateUTC": "2025-03-29T23:27:48.558Z",
  "Data": [1]
}'

Determining Immobilisation Status

We can determine if our message has been actioned and the current status in the following ways:

  1. Field ID 2 – Digital Data

We can simply check the status of the Digital Output we have set up with function Immobiliser in the next message(s) up from the device.

  1. Log Reason 38 (Immobiliser On) and 39 (Immobiliser Off)

The device will generate these logs when immobilisation is turned on or off. 

api integration lock assets

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Bolt2 - Getting Started
  • Hawk - Under Voltage Lockout
  • Hawk - Configure MaxBotix MB7040 I²C Ultrasonic Range Sensor

Subscribe to Partner News

Subscribe to our mailing list to receive Digital Matter news, product and tehnical updates, and more.

Subscribe

Copyright © Digital Matter . All Rights Reserved.

Privacy Contact Support

Knowledge Base Software powered by Helpjuice

Expand