      Device Manager WebAPI Payload Monitoring Output State Controlling the Output from Telematics Guru

      The Hawk has various digital outputs available, based upon which plug in I/O card is used.

      • Switched Ground
      • 3V3 output
      • VBoost Output (can be configured to 5V or 12V)

      See Hawk Baseboard + Plug in Cards - Wiring+Pin Out

      All 3 outputs can be controlled from the server. However the Hawk also has the ability to configure a variety of on-board control options - such as turning on an output based on a certain sensor reading - i.e. turn on a pump if tank level is too low. 

      The output active levels are configured on the Plug In Card parameter tabs

      Device Manager WebAPI

      See Welcome to Device Manager API for message details which can be sent to Device Manager and actioned on devices. Messages will be received and actioned by devices the next time they connect in.

      To control outputs, message 0x004 - Set Digital Output is used. Users must authenticate with their Device Manager username and password or API credentials. 

      Payload

      Data structure for to set digital outputs.

      Offset Length Data Type Description
      0 2 UINT16 Logical level
      b0 – output 0 logical level: On = 1; Off = 0
      b1 – output 1 logical level: On = 1; Off = 0
      b2 – etc.
      2 2 UINT16 Change mask
      b0 – set output 0 according to logical level
      b1 – set output 1 according to logical level

      JSON Example
      {
      "MessageType":4,
      "CANAddress":4294967295,//0xFFFFFFFF,//HOST_ADDRESS
      "Data":[15,15,6,0],
      "ExpiryDateUTC":"2020-03-18T18:25:43.511Z"
      }

      This results in:
      Change mask of 0xFF - i.e. set all outputs according to the logical level.
      Output 1 and 2 (0110 = 6) are turned on, all others turned off.

      Monitoring Output State

      We can see if the change to the output has been made by checking the state of outputs in the Digital Data field (FID=2)

      Additionally if we configure the Input Monitor to log when the output changes, we will see log reason 10 - Digital Output Changed when the output changes. 

      Controlling the Output from Telematics Guru

      Please see Digital Outputs - Introduction for more information on how to remotely control the Hawk's digital output from Telematics Guru.

      • 3v3 - Digout 0
      • Vboost - Digout 1
      • SWGND- Digout 2
      server output hawk control

      Was this article helpful?

      Yes
      No
      Give feedback about this article

      Related Articles

      • Hawk - Digital Outputs behaviour across resets
      • Configuring Sensor Restarts Via Switch Ground

      Subscribe to Partner News

      Subscribe to our mailing list to receive Digital Matter news, product and tehnical updates, and more.

      Subscribe

      Copyright © Digital Matter . All Rights Reserved.

      Privacy Contact Support

      Knowledge Base Software powered by Helpjuice

      DM Logo
      Expand