Contact Us

    If you still have questions or prefer to get help directly from an agent, please submit a request.
    We’ll get back to you as soon as possible.

    Please fill out the contact form below and we will reply as soon as possible.

    • Digital Matter Site
    • Contact Us

    IoT Devices - Analogue Input

    Written by Matthew Clark-Massera

    Updated at January 27th, 2023

      Contact Us

      If you still have questions or prefer to get help directly from an agent, please submit a request.
      We’ll get back to you as soon as possible.

      Contact Support
      • Home
      • Devices
      • LoRaWAN® - General

      Table of Contents

      Auto-Ranging

      The SensorData and SensorNode have analogue inputs available - consult the Datasheet for the number available and input range. 

      Outputs on the device can be enabled just before sampling, to power external sensors. Sampling occurs over roughly 100 ms, in which multiple readings are taking, and the average is calculated to be sent over the network. The following parameters are configurable:

      Enable 3.3V: Enables the 3.3V output when taking a sample.

      Enable Vout:  Enables Vout when taking a sample. This can be either 6 or 12V, depending on whether output boost is enabled on the circuit board (using the jumper).

      NB: The SensorData Sigfox v2 does not have this feature - it will support higher voltage batteries (up to 16V) which must be used if 12V is required for Vout

      Power On Delay: How many seconds after enabling outputs the device will wait, before taking a sample. Can be used to give external sensors enough time to power on fully. This delay is ignored if no outputs are to be enabled.

      Auto-Ranging

      The SensorData and SensorNode have analogue inputs available with a 0-30V input range. The auto-ranging operates as follows:

      • It can either be 0-5V, or 0-30V
      • When taking a sample, it first takes a reading at the 0-30V, if it’s below that, it switches to 0-5V (and then takes more readings, and averages them)
      • The input uses a 12bit ADC, so 0-5V has a 1.22mV precision, and 0-30V has a 7.32mV precision.
      analog input iot devices

      Was this article helpful?

      Yes
      No
      Give feedback about this article

      Related Articles

      • DM LoRaWAN™ Default Application EUI's (AppEUI)
      • LoRaWAN® Config Cable
      • IoT Devices - Schedules
      • LoRaWAN® Overview

      Subscribe to Partner News

      Subscribe to our mailing list to receive Digital Matter news, product and tehnical updates, and more.

      Subscribe

      Copyright © Digital Matter . All Rights Reserved.

      Privacy Contact Support

      Knowledge Base Software powered by Helpjuice

      DM Logo
      Expand