Disable In Trip Logging
For some applications, it may not be necessary to log or upload during trips.
For config per device, please see below:
Oyster Edge, Yabby Edge, Barra Edge, Barra Core, Barra GPS
The above devices can track based on the following modes:
- Movement Based - based on accelerometer activity
- Periodic Mode - update on an interval
Once the device detects it's in motion, it will start logging records and uploading based on the below default parameters.
For some applications, it may not be necessary to log or upload during trips. Firmware version 1.8+ provides the ability to disable In-Trip logging and upload.
To disable in trip logging and upload, from Parameters > Movement Detection, and set the below.
The above parameters mean that the device will only upload during the start and end of a trip. It will not log/upload while in trip.
Oyster3, Yabby3, Remora3
The Oyster3, Yabby3 and Remora3 have slightly different logging functionality to the devices in the other tab.
There isn't a hard and fast way to disable all logging from trips. You can hack this functionality together by increasing the “In Trip Upload Period” and “In Trip Logging Period” to some very high threshold e.g. 2 or 3 hours.